pompy i systemy pompowe  
 
 


Charakterystyki pomp GAB.5

Nazwa Wartości Wykresy
GAB.5.04
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   24232218124
GAB.5.06
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   38363328207
GAB.5.08
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   514844382610
GAB.5.10
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   676460493313
GAB.5.13
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   868378644418
GAB.5.15
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   1009790735021
GAB.5.17
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   114111103835624
GAB.5.19
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   124122115936327
GAB.5.21
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   1371341281077431
GAB.5.23
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   1511481411198339
GAB.5.25
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   1711661561349948
GAB.5.28
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   18818217314510349
GAB.5.31
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   20419718615711249
GAB.5.33
 Q [m3/h] =   0 3.6 6 9 12 15
 H [m] =   21721019816711950




Hydro-Vacuum S.A.
ul. Droga Jeziorna 8
86-303 Grudziądz
tel. 56 45 07 415
fax. 56 46 25 955
Copyright © Hydro-Vacuum S.A.

Informujemy, iż w celu optymalizacji treści dostępnych w naszym serwisie, dostosowania ich do indywidualnych potrzeb każdego użytkownika, jak również dla celów statystycznych korzystamy z informacji zapisanych za pomocą plików cookies na urządzeniach końcowych użytkowników. Pliki cookies użytkownik może kontrolować za pomocą ustawień swojej przeglądarki internetowej. Dalsze korzystanie z naszego serwisu internetowego, bez zmiany ustawień przeglądarki internetowej, oznacza, iż użytkownik akceptuje politykę stosowania plików cookies, opisaną w Polityce prywatności